Home » Shop » hot sale » Chattanooga Intelect Legend XT Channel 3 and 4 Electrotherapy Module

Chattanooga Intelect Legend XT Channel 3 and 4 Electrotherapy Module

Original price was: $686.59.Current price is: $362.17.

Sale!
SKU: 12051 Category:

Features

  • Chattanooga Intelect Legend XT Channel 3 and 4 Electrotherapy Module is ideal for the growing clinic or the clinician on a budget
  • Color-coded front access panel that hides excessive connections and lead wires
  • Upgrade therapy unit to 4 independent channels available from 2 channels
  • Can be used as an accessory with the following models:
    – Chattanooga Intelect Legend XT 4 Channel Electrotherapy System (Code: 2786)

More Information

  • Installation Procedure:
    –
    Disconnect the Mains Power Cord from the power supply. Remove the Rear Access Panel and disconnect the Mains Power Cord from the Therapy System
    – Remove the Front Access Cover and disconnect the Lead Wires and Accessories
    – Remove the Therapy System from the Therapy System Cart, if equipped. Place Therapy System face down on a clean working surface protected with a soft, clean fabric to prevent damage to the lens
    – Do not remove the sEMG Module, if installed
    – Remove and discard the vinyl label holding the Ribbon Cable in the cavity
    – Carefully unroll the Ribbon Cable, making certain not to disconnect it from the Therapy System
    – Carefully align the Ribbon Cable Connector to the Module Connector Pins and press down to connect
    – Set the Therapy System on the Module
    – Make certain the Feet of the Therapy System are resting in the Module Indents
    – Carefully place the Therapy System and Module on one side
    – Tighten screws until the Module does not move on the Therapy System
    – Remove the screw retaining the existing Front Access Panel
    – Install Lanyard to the new Extended Front Access Panel using the same screw
    – Install Lead Wires and additional accessories to Front Panel
    – Install the new Extended Front Access Panel onto Therapy System
    – Make certain Lanyard does not become kinked
    – Connect the Mains Power Cord to the Therapy System
    – Install Rear Access Panel. Connect the Mains Power Cord to an approved power source
    – Turn the System On using the On/Off Switch
    – The System will automatically recognize the added Module and display a configuration change message
    – Read and carefully follow the instructions on the screen
  • Maintenance:
    –
    Clean the system with a clean, lint free cloth moistened with water and mild antibacterial soap. Do not submerse the system in liquids
    – Clean the Therapy System Screen Lens using NOVUS Polish System